You can configure the interlock settings on the Unit-wide
parameters subpage of the Powered by Genetec page.
What you should know
An interlock (also known as sally port or airlock) is an
access restriction placed on a secured area that permits only one perimeter door to be
open at any given time. All perimeter doors within a secured
area must be managed by the same Axis Powered by Genetec unit to ensure proper interlock
functionality.
Procedure
In the Powered by Genetec page, click the Unit-wide
parameters tab.
In the Interlock configuration section, configure the
following:
Single door unlock
Only unlock one door at any given time.
Single door open
The moment one door is open, immediately lock all other doors.
Operators can unlock doors regardless of interlock state
Enable manual unlocking of doors using the Unlock button in
the Door widget, even when the doors are locked due to interlock. You can
apply this setting with either of the interlock options: Single door unlock
or Single door open.
To configure this feature, you must set it up for each
Axis Powered by Genetec unit that manages doors configured in an interlock. Keep
in mind that modifying this setting needs a software restart.