Feature group Security Center feature Supported
Door behavior settings Maintenance mode (keep door unlocked and ignore all access events) Yes
Standard grant time Yes
Extended grant time Yes
Entry time (Standard/Extended)1 Yes
Door relock - options Yes
When door is unlocked by schedule - options Yes
Door held - options Yes
Door forced open - options Yes
Unlock schedules Yes
Request to exit (REX) options
Unlock on REX (On/Off) Yes
Time to ignore REX after granting access (in seconds) Yes
Ignore REX events while door is open (On/Off) Yes
Time to ignore REX after door closes (in seconds) Yes
Visitor escort and two-person rule
Maximum delay between card presentation (in seconds) Yes
Enforce two-person rule (On/Off) on Door side Yes
Manual actions on doors in Security Desk2 Manually unlock doors Yes
Reader shunting (activate/deactivate reader) Yes
Override unlock schedules Yes
Live event monitoring in Security Desk Module running state (Online, Offline) Yes
AC fail No
Battery fail (Low battery) No
Door open/closed Yes
Door locked/unlocked Yes
Door forced open Yes
Door held open for too long Yes
Duress PIN Yes
Area restrictions (for secured areas)3 Minimum security clearance (part of threat level management) Yes
Visitor escort rule (On/Off) Yes
Visitor escort with turnstile - Single passage mode Yes
Visitor escort with turnstile - Delegation mode Yes
Interlock Yes
Antipassback
Hard (log and deny access on Antipassback violation) Yes
Presence timeout (forget area presence after a certain delay) Yes
Strict (antipassback checked on both area entrance and exit) Yes
On schedule Yes
Max occupancy Yes
Global antipassback4 Yes
First-person-in rule
Enforce on door unlock schedule Yes
Enforce on access rules Yes
Elevator control Elevators No
Zone management5 I/O zone Yes
Hardware zone
Zone arming input Yes
Zone arming schedule Yes
Zone arming and entry delays Yes
Zone I/O linking Yes
Countdown buzzer No
Unit management Centralized firmware upgrade Yes6
Centralized password management Yes6
Centralized certificate management No

1 Security Center requires an entry sensor to accurately detect entry into an area. In the absence of the entry sensor, Security Center uses the door sensor, and the Entry detected event is generated when the door sensor is triggered. In the absence of both sensors, Security Center generates the Entry assumed event when access is granted.

2 The Synergis™ unit must be connected to the Access Manager.

3 Supported features are limited to the secured area managed by the Axis Powered by Genetec controller.

4 Requires Security Center 5.12.0 or later, and Synergis Softwire 11.5.0 or later.

5 Prior to Security Center 5.12.0 and Synergis Softwire 11.5.0, zone management is limited to zones managed by the same Axis Powered by Genetec controller.